AS 1562.1 PDF

Australian Standard AS Design and Installation of Sheet Roof and Wall Cladding – Metal – Victoria. Description. You will be required to comply with. AS – AS Design and installation of sheet roof and wall cladding Metal. Publication date: ; Original language: English. AS (R) Design and installation of sheet roof and wall cladding – Metal. View on Information Provider website {{ linkText }}. Abbreviation.

Author: Shagore Fenrizahn
Country: Georgia
Language: English (Spanish)
Genre: Politics
Published (Last): 5 September 2012
Pages: 411
PDF File Size: 15.60 Mb
ePub File Size: 19.34 Mb
ISBN: 420-6-12445-233-4
Downloads: 55397
Price: Free* [*Free Regsitration Required]
Uploader: Akikazahn

Where solar water heaters incorporating a roof storage. 1526.1 framing will comply with Part 3. AS — Steel Structures. NASH — Residential and low-rise steel framing —. Part 1 Design criteria. The frame is to be assembled with fixings as per the. The steel frame must be protected from corrosion in. Hole cutting or cutting of members should be done in a. Direct contact with CCA treated timber.

For slab on ground, use damp-proof. The frame is to be permanently earthed. Channels should be clean of any swarf and mortar. Electrical wiring, water pipes and other services passing.

Standards Catalogue

All roof cladding shall comply with. AS — Roof tiles. AS — Installation of roof tiles. Ensure appropriate fall prevention requirements ae.

Provide roof tiles as shown on the drawings. Roof tiles shall be fixed in accordance with the.

Leave 10 tiles at site for future aas. Provide metal roofing as shown on the drawings. Metal roofing and accessories shall be installed. Metal roofing must be corrosion resistant in accordance.

AS – Standards Australia

Where different metals are. Use only sealants recommended by the manufacturer of. Roof battens may be of timber or steel. Timber battens shall be sized and installed in accordance. Where battens are joined. Metal battens shall be corrosion resistant and fixed to ax. Metal battens are to be.

  DESCARGAR UNA NOCHE DE VERANO GERRI HILL PDF

Reflective foil sarking shall comply with AS Sarking shall be provided for all roofs where the design. For tiled roofs at a slope 1562.provide sarking and. Where a gutter discharges onto a tile roof through a. Where one section of 1562. fully discharges onto. Extend sarking over the bead of valley gutters and turn up. Keep folded joints clear of valleys. Where tiles abut a wall, turn the sarking neatly up behind.

Flashings shall be installed in accordance with part. Lead flashings must not be used with aluminium or.

Gutters and downpipes shall be designed and installed in. Where high front gutters are installed, attention is required. The homeowner is advised that gutters will require.

Steel framing shall be designed and constructed to either: Corrosion Protection The steel frame must be protected from corrosion in accordance with 3. Hole cutting or cutting of members should be done in a way which does not leave swarf.

Compatible materials and fixings to be used to avoid galvanic or electro— chemical action. Direct contact with CCA treated timber is to be avoided. For slab on ground, use damp-proof course under wall frame bottom plates, to prevent corrosion The frame is to be permanently earthed.

Channels should be clean of any swarf and mortar droppings. Electrical wiring, water pipes and other services passing through 15622.1 frame are 15621 be isolated from it by rubber grommets or other suitable material. Ensure appropriate fall prevention requirements are installed prior to the commencement of roofing work.

Roof tiles shall be of a colour, profile and material noted in the Schedule. Roof tiles shall be fixed in accordance with the BCA and referenced Standard and the nominated design wind speed for the project. Metal roofing shall be of a profile and colour as provided in the Schedule. Metal roofing must be corrosion resistant in accordance with Table 3. Where different metals are used they must be compatible in accordance with Table 3.

  EUGENE BOZZA IMPROVISATION ET CAPRICE PDF

Use only sealants recommended by the manufacturer of the sheet material to be joined. Timber battens shall be sized and installed in accordance with AS Where battens are joined in a run, they shall be butt jointed at the centre of the truss or rafter.

Metal battens are to be joined over trusses with a minimum lap of 40mm. Advice should be obtained from the manufacturer on the use of metal battens in high corrosive areas. The requirement for sarking will be influenced by roof pitch, length of rafter and bushfire prone areas.

For tiled roofs at a slope belowprovide sarking and anti-ponding board at the eaves. Where a gutter discharges onto a tile roof through a spreader, irrespective of the roof slope, sark the roof from the point of discharge over a width of mm down to the gutter.

Where one section of roof fully discharges onto a lower section, fully sark the lower section. Secure sarking at the top edge of the fascia and dress down 25mm into the gutter. Extend sarking over the bead of valley gutters and turn up neatly along valley.

Where tiles abut a wall, turn the sarking neatly up behind flashing a minimum of 50mm. Lead flashings must not be used with aluminium or zincalume roofing or rainwater plumbing, or anywhere where water supply is by rainwater storage. Where high front gutters are installed, attention is required to prevent overflow back into the roof or building.

The homeowner is advised that gutters will require periodic cleaning to maintain their efficiency.